Aprilent Systems

eSSL EBS-5030A

Technical Specifications

  • Color management architectures Different color, different matter;
  • white/black/colorized For comparing these images to find the suspected dangerous goods;
  • To eliminate organic. Inorganic out ln view of the most important image;
  • Edge enhancement The edge of image is more clear;
  • High penetration Make the image more through, to look every goods in one image;
  • Zoom in/zoom out Make the image bigger, make the image smaller;
  • times size of image Make image back to 1 times size of image;
  • Brighter/darker Make image more bright /make image darker;
  • Replay Playback all images on the screen at current, be able to do the next steps

Description

  • Single-Energy, L-shaped array detector
  • Display date/time baggage counter User ID number
  • One-key shutdown control, Just rotate the key to shut down the machine; it is safe, easy, and convenient
  • High-resolution PHILIP 19-inch color LCD display
  • X-ray sensor—L-type photodiode array detector (energy), 24-bit depth
  • Image Storage—100,000 pictures in real time (can be customized)
  • Orientation : Upward;
  • Tube Current : 0.6mA;
  • Anode voltage : 80KV X ray Generator (adjustable);
  • X-ray divergence angle : 60 °;
  • Generator cooling/working periods: sealed oil bath with forced air/100%;
  • Single Direction : Bidirectional (IN /Out Optional & amp; customized)
  • Windows based operating system
  • Image Output : Color/BW, Negative, High/Low penetration, Organic /Inorganic
  • Accessories : 19 Inch LCD Monitor, Foldable Keyboard, Baggage Collection Tray & amp; Tool kit
  • Product Weight : 410Kg
  • Package Dimension : 1810*910*1450

General Specifications

  • Tunnel Size : 500 (W) ×300 (H) mm
  • Conveyor Speed : 0.22m/s
  • Conveyor Max Load : 150 kg
  • Single inspection dosage : < 1.32μGy
  • Leakage radiation : < 0.06μGy/h
  • Wire Resolution : 40 AWG(0.0787mm metal line)
  • Steel Penetration : 10mm
  • Film Safety : For ISO 1600
  • Storage Temperature : -20°C to 60°C
  • Operating Temperature : 0°C to 45°C

X Generator

  • Orientation : Upward
  • Tube Current : 0.4~0.7MA (adjustable)
  • Anode voltage : 80KV (adjustable)
  • X-ray divergence angle : 60 °
  • Generator cooling/working periods : sealed oil bath with forced air/100%
  • X-RAY SENSOR : L-shaped array detector, 24bit